Verderflex Rapide R8

Maximum Flow Rate

470 l/hr (7800 ml/min)

Maximum Discharge

2 Bar

Standard Speeds

68, 137 and 196 RPM

Control

Inverter Optional

Protection Class

IP55

Voltage

230/400V 50Hz / 265/460V 60Hz (Single Phase Available to special order)

Installed Motor power

0.18 kW 50Hz / 0.25HP 60Hz

Standard Tubes

Verderprene, Silicone

Tube Size

12.7 x 3.2 mm

Weight

7kg

ATEX

None

Typical Flow Rates - Verderflex Rapide R8

Tube

RPM

Flow ml/min

Flow l/hr

12.7 x 3.2

68

2800

170

12.7 x 3.2

*89

3650

220

12.7 x 3.2

137

5000

330

12.7 x 3.2

196

7800

470

Nominal pump speed based on 50Hz operation
*89 RPM is a non-standard speed

Verderflex Rapide R8 applications